Interrupt List - Release 61 (16jul00)
⇤
⇠
⇧
🏠
∕
HTML Edition
∕
Browse the Index
∕
INT 23
⇢
⇥
RBIL61 - INT 23
INT 15 - VMiX -
"sys_wake"
- WAKE SLEEPING PROCESS
{#idx18148}
INT 1B - KEYBOARD - CONTROL-BREAK HANDLER
{callout or callback}
{#idx39206}
{#idx39208}
INT 21 - DOS 1+ - BUFFERED INPUT
{#idx41682}
INT 21 - DOS 1+ - CHARACTER INPUT WITHOUT ECHO
{#idx41659}
INT 21 - DOS 1+ - CREATE NEW PROGRAM SEGMENT PREFIX
{#idx43460}
INT 21 - DOS 1+ - GET STDIN STATUS
{#idx41703}
INT 21 - DOS 1+ - READ CHARACTER FROM STANDARD INPUT, WITH ECHO
{#idx41547}
INT 21 - DOS 1+ - READ CHARACTER FROM STDAUX
{#idx41586}
INT 21 - DOS 1+ - TERMINATE PROGRAM
{#idx41525}
INT 21 - DOS 1+ - WRITE CHARACTER TO PRINTER
{#idx41617}
INT 21 - DOS 1+ - WRITE CHARACTER TO STANDARD OUTPUT
{#idx41577}
INT 21 - DOS 1+ - WRITE CHARACTER TO STDAUX
{#idx41600}
INT 21 - DOS 1+ - WRITE STRING TO STANDARD OUTPUT
{#idx41675}
INT 21 - DOS 3.0+ internal - GET ADDRESS OF DOS SWAPPABLE DATA AREA
{
undocumented
Information about a product which is not publicly available from the manufacturer, and must be determined by reverse-engineering (disassembly, trial-and-error, etc.). Undocumented information tends to change -- often dramatically -- between successive revisions of a product, since the manufacturer has no obligation to maintain compatibility in behavior which is not explicitly stated.
}
{#idx53113}
INT 21 - DOS 4.x only - internal - GET DOS SWAPPABLE DATA AREAS
{obsolete,
undocumented
Information about a product which is not publicly available from the manufacturer, and must be determined by reverse-engineering (disassembly, trial-and-error, etc.). Undocumented information tends to change -- often dramatically -- between successive revisions of a product, since the manufacturer has no obligation to maintain compatibility in behavior which is not explicitly stated.
}
{#idx53349}
INT 21 - DR DOS 5.0+ internal - GET POINTER TO INTERNAL VARIABLE TABLE
{
undocumented
Information about a product which is not publicly available from the manufacturer, and must be determined by reverse-engineering (disassembly, trial-and-error, etc.). Undocumented information tends to change -- often dramatically -- between successive revisions of a product, since the manufacturer has no obligation to maintain compatibility in behavior which is not explicitly stated.
}
{#idx50115}
INT 21 - PTS-DOS 6.51 & S/DOS 1.0 - ABORT CURRENT PROCESS VIA INT 23
{
undocumented
Information about a product which is not publicly available from the manufacturer, and must be determined by reverse-engineering (disassembly, trial-and-error, etc.). Undocumented information tends to change -- often dramatically -- between successive revisions of a product, since the manufacturer has no obligation to maintain compatibility in behavior which is not explicitly stated.
}
{#idx57176}
{#idx57189}
INT 22 - COMTROL HOSTESS i/
ISA
(Industry-Standard Architecture) The expansion bus used by the
IBM
International Busiuness Machines
PC
IBM PC
/
AT
IBM PC AT
. See also EISA.
DEBUGGER - CHANGE FIRMWARE DEBUGGING
PORT
IBM PC Portable (uses same BIOS as XT)
{#idx72030}
INT 23 - COMTROL HOSTESS i/
ISA
(Industry-Standard Architecture) The expansion bus used by the
IBM
International Busiuness Machines
PC
IBM PC
/
AT
IBM PC AT
. See also EISA.
DEBUGGER - GET CONFIGURATION INFORMATION
{#idx72064}
INT 23 - DOS 1+ - CONTROL-C/CONTROL-BREAK HANDLER
{#idx72036}
{#idx72049}
{#idx72057}
INT 26 - COMTROL HOSTESS i/
ISA
(Industry-Standard Architecture) The expansion bus used by the
IBM
International Busiuness Machines
PC
IBM PC
/
AT
IBM PC AT
. See also EISA.
DEBUGGER - ENTER/EXIT EXTENDED ADDRESSING MODE
{#idx72494}
INT 27 - DOS 1+ - TERMINATE AND STAY RESIDENT
{#idx72502}