Interrupt List - Release 61 (16jul00)
⇤
⇠
⇧
🏠
∕
HTML Edition
∕
Browse the Index
∕
INT 68
⇢
⇥
RBIL61 - INT 68
Bibliography
{#idx166714}
INT 41 - MS Windows debugging kernel -
"OutputDebugString"
{callout or callback, protected mode,
undocumented
Information about a product which is not publicly available from the manufacturer, and must be determined by reverse-engineering (disassembly, trial-and-error, etc.). Undocumented information tends to change -- often dramatically -- between successive revisions of a product, since the manufacturer has no obligation to maintain compatibility in behavior which is not explicitly stated.
}
{#idx100109}
INT 41 - MS Windows debugging kernel - DEBUGGER INSTALLATION CHECK
{callout or callback, protected mode,
undocumented
Information about a product which is not publicly available from the manufacturer, and must be determined by reverse-engineering (disassembly, trial-and-error, etc.). Undocumented information tends to change -- often dramatically -- between successive revisions of a product, since the manufacturer has no obligation to maintain compatibility in behavior which is not explicitly stated.
}
{#idx100119}
INT 66 - Newkey v5.4 - INSTALLATION VECTOR
{#idx115009}
INT 67 - Sangoma CCPOP 3270 resident module
{#idx115606}
INT 68 - ??? - INSTALLATION CHECK???
{
undocumented
Information about a product which is not publicly available from the manufacturer, and must be determined by reverse-engineering (disassembly, trial-and-error, etc.). Undocumented information tends to change -- often dramatically -- between successive revisions of a product, since the manufacturer has no obligation to maintain compatibility in behavior which is not explicitly stated.
}
{#idx118259}
INT 68 - ???
{
undocumented
Information about a product which is not publicly available from the manufacturer, and must be determined by reverse-engineering (disassembly, trial-and-error, etc.). Undocumented information tends to change -- often dramatically -- between successive revisions of a product, since the manufacturer has no obligation to maintain compatibility in behavior which is not explicitly stated.
}
{#idx118265}
INT 68 - APPC/
PC
IBM PC
- CHANGE LOGICAL UNIT
{#idx118142}
INT 68 - APPC/
PC
IBM PC
- CHANGE NUMBER OF SESSIONS
{#idx118212}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - ALLOCATE
{#idx117504}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - CONFIRM
{#idx117589}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - CONFIRMED
{#idx117619}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - DEALLOCATE
{#idx117650}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - FLUSH
{#idx117688}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - GET ATTRIBUTES
{#idx117717}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - GET CONVERSATION TYPE
{#idx117762}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL -
POST
see Power-On Self-Test
ON RECEIPT
{#idx117793}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - PREPARE TO RECEIVE
{#idx117823}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - RECEIVE AND WAIT
{#idx117857}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - RECEIVE IMMEDIATE
{#idx117896}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - REQUEST TO SEND
{#idx117933}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - SEND DATA
{#idx117965}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - SEND ERROR
{#idx117996}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - TEST
{#idx118033}
INT 68 - APPC/
PC
IBM PC
- CONNECTION CONTROL - WAIT
{#idx118065}
INT 68 - APPC/
PC
IBM PC
- CONVERT
{#idx118292}
INT 68 - APPC/
PC
IBM PC
- ENABLE/DISABLE
API
(Application Program[ming] Interface) The defined set of calls which a program may make to interact with or request services of the operating system or environment under which it is running. Because the inputs and outputs of the calls are well-defined, a program using the API can continue using the identical calls even if the internal organization of the program providing the API changes.
VERB TRACING
{#idx118326}
INT 68 - APPC/
PC
IBM PC
- ENABLE/DISABLE APPC
{#idx118280}
{#idx118290}
INT 68 - APPC/
PC
IBM PC
- ENABLE/DISABLE MESSAGE TRACING
{#idx118315}
INT 68 - APPC/
PC
IBM PC
- GET ALLOCATE
{#idx118118}
INT 68 - APPC/
PC
IBM PC
- NETWORK DEVICE CONTROL - ACTIVATE DLC
{#idx117478}
INT 68 - APPC/
PC
IBM PC
- NETWORK DEVICE CONTROL - ATTACH LOGICAL UNIT
{#idx117316}
INT 68 - APPC/
PC
IBM PC
- NETWORK DEVICE CONTROL - ATTACH PHYSICAL UNIT
{#idx117281}
INT 68 - APPC/
PC
IBM PC
- NETWORK DEVICE CONTROL - DETACH LOGICAL UNIT
{#idx117428}
INT 68 - APPC/
PC
IBM PC
- NETWORK DEVICE CONTROL - DETACH PHYSICAL UNIT
{#idx117454}
INT 68 - APPC/
PC
IBM PC
- NETWORK DEVICE CONTROL - DISPLAY
{#idx117239}
{#idx117250}
INT 68 - APPC/
PC
IBM PC
- PASSTHROUGH
{#idx118248}
INT 68 - APPC/
PC
IBM PC
- SET PASSTHROUGH
{#idx118349}
{#idx118356}
INT 68 - APPC/
PC
IBM PC
- SET TRACE DESTINATION
{#idx118335}
INT 68 - APPC/
PC
IBM PC
- TP STARTED
{#idx118093}
INT 68 - APPC/
PC
IBM PC
- TRANSACTION PROCESSING
{#idx118170}
INT 68 - APPC/
PC
IBM PC
- TRANSFER MESSAGE DATA
{#idx118189}
INT 68 - HP Vectra
AT
IBM PC AT
- IRQ16 - 8041 SERVICE REQUEST
{callout or callback}
{#idx117225}
INT 68 - MS Windows debugging kernel - OUTPUT STRING
{#idx118272}
INT 68 - Novell NetWare LU6.2
{#idx117213}
INT 68 - Sangoma CCPOP 3270 resident module
{#idx117209}
INT 69 - HP Vectra
AT
IBM PC AT
- IRQ17 - KEYBOARD OUTPUT-BUFFER-FULL SERVICE ROUTINE
{callout or callback}
{#idx118377}
INT 92 - Sangoma X.25 INTERFACE PROGRAM
{#idx127138}
PORT
IBM PC Portable (uses same BIOS as XT)
007C-007D - HP-Vectra - PIC 3 - PROGRAMMABLE INTERRUPT CONTROLLER
(8259)
{#idx140416}