INT F7 - FSBBS 2.0 - CONFIGURATION RECORD AH = 00h AL = function 00h get configuration record Return: DS:DX -> configuration record 01h set configuration record Return: nothing 02h get path for option DS:DX -> option name Return: DS:DX -> path 03h determine whether configuration record set Return: AX = status 0000h set 0001h not yet set 04h get link state Return: AX = state 0000h unlinked 0001h linked Notes: this information is preliminary and still subject to change all of the INT F7 calls for FSBBS are used for interprogram communication between the BBS kernel and the programs it spawns SeeAlso: AH=01h