INT E6 C - CP/M-86 v1.1 - XIOS INTERRUPT / UNKNOWN DISK DRIVE
AX = function which accessed drive
0000h SELDSK
0001h READ
0002h WRITE
0003h HOME
DX:BX -> parameter block (see #04063)
Return: AX = return value
Desc: called by CP/M-86 kernel when an unknown disk drive is used, which
permits an application to provide access services
Notes: This was labelled "XIOS interrupt" in later Digital Research
documentation (CCP/M-86) and "for the version 1.0 back door".
Format of CP/M-86 unknown-drive paramter block:
Offset Size Description (Table 04063)
00h BYTE drive number (00h = first unknown drive, etc.)
01h BYTE deblocking flag (00h = normal write, 01h = directory write)
02h WORD track number
04h WORD sector number
06h DWORD data transfer address
0Ah BYTE verify flag (nonzero to verify writes)
Notes: in CP/M-86 v1.1, this is actually a portion of a BIOS disk data
table which starts one byte before the address given to the INT E6
handler; that extra byte is the current logical drive number