INT 16 - HP Vectra EX-BIOS - "F16_GET_ATTR" - GET CURRENT TYPEMATIC VALUES
	AX = 6F02h
Return: AH = 00h (successful)
	CX = 0004h (size of returned buffer)
	ES:SI -> buffer for typematic info (see #00596)
Note:	supported by the original HP Vectra ATIBM PC AT and ES/QS/RS series HP Vectras
SeeAlso: AX=6F00h,AX=6F02h,AX=6F03h,AX=6F04h
SeeAlso: AX=6F00h,AX=6F01h,AX=6F03h