INT 14 - ARTICOM - GET ASYNCHRONOUS REDIRECTOR STATUS                           
	AX = 8002h
	ES:DI -> buffer for redirector status structure (see #00359)
Return: AX = error code, if error (see #00360)
SeeAlso: AX=8000h"ARTICOM",AX=8003h"ARTICOM"


Format of ARTICOM redirector status:
Offset	Size	Description	(Table 00359)
 00h	WORD	redirector major and minor version numbers
 02h	WORD	redirectable ports found
 04h	WORD	redirectable ports + local ports found
 06h	WORD	redirector internal buffer size
 08h	WORD	maximum servers maintained
 0Ah	WORD	number of adapters found
                                                                                

INT 14 - COMM-DRV v14.0 - READ PORTIBM PC Portable (uses same BIOS as XT) METRICS - GET PORTIBM PC Portable (uses same BIOS as XT) PARAMETERS
	AX = 8002h
	DX = port number
Return: AH bit 7 set on error
	AH bit 7 clear if successful
	    BX:DI -> Port Control Block (see #00367) (modifyable portion only)