INT 21 - Novell NetWare - BINDERY SERVICES - READ PROPERTY VALUE                
	AH = E3h subfn 3Dh
	DS:SI -> request buffer (see #01942)
	ES:DI -> reply buffer (see #01943)
Return: AL = status (see #01941)
Desc:	retrieve one 128-byte segment of the specified property's value
Note:	this function is supported by Advanced NetWare 1.0+ and Alloy NTNX
SeeAlso: AH=E3h/SF=39h,AH=E3h/SF=3Ch,AH=E3h/SF=3Eh,AX=F217h/SF=3Dh


(Table 01941)
Values for NetWare function status:
 00h	successful
 96h	server out of memory
 E8h	not item property
 ECh	no such segment
 F0h	wildcard not allowed
 F1h	invalid bindery security level
 F8h	not permitted to write property
 F9h	not permitted to read property
 FBh	no such property
 FCh	no such object
 FEh	server bindery locked
 FFh	bindery failure
SeeAlso: #01937,#01946


Format of NetWare "Read Property Value" request buffer:
Offset	Size	Description	(Table 01942)
 00h	WORD	length of following data (max 44h)
 02h	BYTE	3Dh (subfunction "Read Property Value")
 03h	WORD	(big-endian) type of object
 05h	BYTE	length of object's name (01h-2Fh)
 06h  N BYTEs	object name
	BYTE	segment number (01h on first call, increment until done)
	BYTE	length of property's name (01h-0Fh)
      N BYTEs	property name
SeeAlso: #01943,#02188


Format of NetWare "Read Property Value" reply buffer:
Offset	Size	Description	(Table 01943)
 00h	WORD	(call) 0082h (length of following results buffer)
 02h 128 BYTEs	property's value
 82h	BYTE	more segments (00h no, FFh yes)
 83h	BYTE	property's flags
SeeAlso: #01942,#02188