INT 15 - DESQview 2.20+ - SEND MESSAGE - "SETPRI" - SET PRIORITY WITHIN OBJECTQ
	AH = 12h
	BH = 06h
	BL = object
	    00h object handle in DWORDDoubleword; four bytes.	 Commonly used to hold a 32-bit segment:offset or selector:offset address. on top of stack
		mailbox, keyboard, pointer, or timer
		(DV 2.50+) window
	    01h (DV 2.50+) current task's window
	    04h given task's keyboard (task's handle on top of stack)
	    05h current task's default keyboard
	STACK: DWORDDoubleword; four bytes.	 Commonly used to hold a 32-bit segment:offset or selector:offset address. new priority of object in task's OBJECTQ
			(new priority of task if window handle)
Return: STACK popped
Notes:	initially all objects have the same default value.  Should only make
	  relative adjustments to this default value.
	when changing priorities, all objects already on the objectq are
	  reordered
	for window handles, only the non-blocked task(s) with the highest
	  priority receive CPU(Central Processing Unit) The microprocessor which executes programs on your computer. time under DESQview 2.50-2.52; the default
	  priority is 0Ah
SeeAlso: AH=12h/BH=07h,AH=12h/BH=87h