Interrupt List - Release 61 (16jul00)
⇤
⇠
⇧
🏠
∕
HTML Edition
∕
Browse the Index
∕
Alloy MW386
⇢
⇥
RBIL61 - Alloy MW386
INT 10 - Alloy MW386 - FORCE WORKSTATION SCREEN UPDATE
{#idx6228}
INT 10 - Alloy MW386 - GET PHYSICAL WORKSTATION ADAPTER TYPE
{#idx6243}
{#idx6249}
INT 10 - Alloy MW386 - GET PHYSICAL WORKSTATION DISPLAY MODE
{#idx6234}
INT 10 - Alloy MW386 - INHIBIT WORKSTATION SCREEN UPDATES
{#idx6253}
INT 10 - Alloy MW386 - REDRAW SCREEN
{#idx6261}
INT 14 - Alloy MW386 v2+ - CHANGE PHYSICAL
PORT
IBM PC Portable (uses same BIOS as XT)
PARAMETERS
{#idx13585}
{#idx13596}
{#idx13602}
INT 14 - Alloy MW386 v2+ - GET
PORT
IBM PC Portable (uses same BIOS as XT)
NUMBER FROM LOGICAL
PORT
IBM PC Portable (uses same BIOS as XT)
ID
{#idx13535}
INT 14 - Alloy MW386 v2+ - RELEASE LOGICAL COMMUNICATIONS
PORT
IBM PC Portable (uses same BIOS as XT)
{#idx13493}
INT 14 - X00
FOSSIL
(Fido/Opus/Seadog Standard Interface Layer) A standardized API for performing serial I/O, originally used by the Fido and Opus bulletin- board software and Seadog bulletin-board mailer, but now in wider use.
- DESTRUCTIVE READ WITH NO WAIT
{#idx13396}
INT 14 - X00
FOSSIL
(Fido/Opus/Seadog Standard Interface Layer) A standardized API for performing serial I/O, originally used by the Fido and Opus bulletin- board software and Seadog bulletin-board mailer, but now in wider use.
- STUFF RECEIVE BUFFER
{#idx13444}
INT 17 - Alloy MW386 - CHANGE TEMPORARY
SPOOL
(Simultaneous Peripheral Operation OnLine) The process of performing output to a slow peripheral such as a printer while other tasks continue running on the CPU. This term dates back to mainframe days before the invention of timesharing.
DRIVE
{#idx29599}
INT 17 - Alloy MW386 - CHECK SPOOLER
{#idx29617}
INT 17 - Alloy MW386 - DEFINE TEMPORARY FILENAME
{#idx29593}
INT 17 - Alloy MW386 - ENABLE/DISABLE BANNER PAGE
{#idx29570}
INT 17 - Alloy MW386 - ENABLE/DISABLE FORM FEED
{#idx29558}
INT 17 - Alloy MW386 - GET DEVICE NAME FROM PHYSICAL DEVICE NUMBER
{#idx29390}
INT 17 - Alloy MW386 - GET PHYSICAL DEVICE NUMBER FROM NAME
{#idx29383}
INT 17 - Alloy MW386 -
SPOOL
(Simultaneous Peripheral Operation OnLine) The process of performing output to a slow peripheral such as a printer while other tasks continue running on the CPU. This term dates back to mainframe days before the invention of timesharing.
COPY OF FILE
{#idx29548}
INT 17 - Alloy MW386 v2+ - GET REAL-TIME PRINTER STATUS
{#idx29606}
INT 17 - Alloy MW386 v2+ - GET/SET
SPOOL
(Simultaneous Peripheral Operation OnLine) The process of performing output to a slow peripheral such as a printer while other tasks continue running on the CPU. This term dates back to mainframe days before the invention of timesharing.
FLAGS
{#idx29581}
INT 7F - Alloy MW386 - ASSIGN DIRECTORY TO GROUP
{#idx126159}
INT 7F - Alloy MW386 - ASSIGN GROUP NAME
{#idx126195}
INT 7F - Alloy MW386 - ASSIGN USER TO GROUP
{#idx126178}
INT 7F - Alloy MW386 - CHANGE CONSOLE MODE
{#idx126004}
INT 7F - Alloy MW386 - CHANGE NAME OF DOS TASK
{#idx126105}
INT 7F - Alloy MW386 - CREATE DOS TASK
{#idx126079}
INT 7F - Alloy MW386 - DOS TASK DELAY
{#idx126140}
INT 7F - Alloy MW386 - ENABLE/DISABLE AUTOBAUD DETECT
{#idx125764}
INT 7F - Alloy MW386 - FLUSH DISK BUFFERS
{#idx126061}
INT 7F - Alloy MW386 - GET DOS TASK PID FROM CREATE ID
{#idx126089}
INT 7F - Alloy MW386 - GET GROUP NAME
{#idx126200}
INT 7F - Alloy MW386 - GET MACHINE, USER, AND PROCESS NUMBER
{#idx125890}
INT 7F - Alloy MW386 - GET NUMBER OF AVAILABLE USER TASKS
{#idx126128}
INT 7F - Alloy MW386 - GET
PORT
IBM PC Portable (uses same BIOS as XT)
INFORMATION
{#idx125702}
INT 7F - Alloy MW386 - GET PROCESS NUMBER FROM TASK NAME
{#idx126121}
INT 7F - Alloy MW386 - GET TASK NAME FROM PROCESS NUMBER
{#idx126112}
INT 7F - Alloy MW386 - GET TERMINAL PARAMETERS
{#idx125749}
INT 7F - Alloy MW386 - GET USER GROUP LIST
{#idx126191}
INT 7F - Alloy MW386 - GET USER LOGIN STATE
{#idx125903}
INT 7F - Alloy MW386 - GET USER NAME
{#idx125885}
INT 7F - Alloy MW386 - GET USER PRIVILEGE LEVEL
{#idx125895}
INT 7F - Alloy MW386 - GET USER STATUS
{#idx125922}
{#idx125932}
INT 7F - Alloy MW386 -
POST
see Power-On Self-Test
EVENT
{#idx126058}
INT 7F - Alloy MW386 -
POST
see Power-On Self-Test
TERMINAL CONFIGURATION CHANGES
{#idx125774}
INT 7F - Alloy MW386 - READ CONSOLE DATA BYTE
{#idx126024}
INT 7F - Alloy MW386 - READ CONSOLE DATA INTO BUFFER
{#idx126031}
INT 7F - Alloy MW386 - READ RESTRICTED DIRECTORY ENTRY
{#idx126164}
INT 7F - Alloy MW386 - READ RESTRICTED DIRECTORY ENTRY FOR GROUP
{#idx126171}
INT 7F - Alloy MW386 - REMOVE DOS TASK
{#idx126132}
INT 7F - Alloy MW386 - REMOVE USER FROM GROUP
{#idx126185}
INT 7F - Alloy MW386 - RESET NETWORK EXECUTIVE
{#idx126044}
{#idx126051}
INT 7F - Alloy MW386 - RESTRICT DIRECTORY TO GROUP
{#idx126151}
INT 7F - Alloy MW386 - SET TERMINAL DRIVER FOR ANOTHER USER
{#idx125738}
INT 7F - Alloy MW386 - SET TERMINAL PARAMETERS
{#idx125756}
INT 7F - Alloy MW386 - SET USER STATUS
{#idx125934}
{#idx125943}
INT 7F - Alloy MW386 - SWITCH TO NEW DOS TASK
{#idx126098}
INT 7F - Alloy MW386 - VERIFY USER PASSWORD
{#idx125911}
INT 7F - Alloy MW386 - WRITE BYTE TO CONSOLE
PORT
IBM PC Portable (uses same BIOS as XT)
{#idx126012}
INT 7F - Alloy MW386 - WRITE BYTE TO TERMINAL AUX
PORT
IBM PC Portable (uses same BIOS as XT)
{#idx125993}
INT 7F - Alloy MW386 v1.x only - CHECK
PORT
IBM PC Portable (uses same BIOS as XT)
ASSIGNMENT
{#idx125712}
INT 7F - Alloy MW386 v2+ - GET MW386 INVOCATION DRIVE
{#idx126070}
INT 7F - Alloy MW386 v2+ - SET ERROR MODE
{#idx125841}
INT 7F - Alloy MW386 v2+ - SET
FCB
see File Control Block
MODE
{#idx125850}
INT 7F - Alloy NTNX - LOCK FILE FOR USER
{#idx125789}
INT 7F - Alloy NTNX - UNLOCK FILE FOR USER
{#idx125813}