Interrupt List - Release 61 (16jul00)
⇤
⇠
⇧
🏠
∕
HTML Edition
∕
Browse the Index
∕
AMI
⇢
⇥
RBIL61 - AMI
Bibliography
{#idx167430}
{#idx167459}
CALL xxxxh:xxxxh - Alternate Multiplex Interrupt Specification TSRs
{#idx159414}
{#idx159419}
CALL xxxxh:xxxxh - Interrupt Sharing Protocol
{#idx159641}
{#idx159646}
CMOS
(Complementary Metal-Oxide-Semiconductor) A type of integrated circuit design known for its low power consumption.
37h -
IBM
International Busiuness Machines
International Busiuness Machines) A hardware, software and other service technology company founded in 1911.
PS/2
IBM PS/2, any model
- DATE CENTURY BYTE
{#idx169358}
HTML Edition
{../}
I2C
(also IIC; the "2" is superscripted) Inter-Integrated Circuit Bus -- A moderate-speed serial communications bus originally invented by Philips in the early 1980s for consumer-electronics applications, such as inter-chip communication in a television set or high-end stereo. The I2C bus has recently appeared on PCs in video capture boards and similar devices, as well as (surprisingly) SDRAM DIMMs (for the on-board serial EEPROM). The ACCESS.bus is a derivative of the I2C bus which forms the physical layer of the Universal Serial Bus. Similary, the SMBus (System Management Bus) also uses I2C as its physical layer.
86h/00h - ITT VPX 32xx/322xD - JEDEC MANUFACTURER ID
{#idx170482}
INT 15 - AMIGATSR - INSTALLATION CHECK
{#idx20735}
{#idx20741}
{#idx20757}
INT 16 - TSRBONES - INSTALLATION CHECK
{#idx25807}
INT 21 - CD-ROM device driver - IOCTL INPUT
{#idx46426}
INT 21 - DOS 3.3+ - SET GLOBAL CODE PAGE TABLE
{#idx55578}
INT 2D - ALTERNATE MULTIPLEX INTERRUPT SPECIFICATION
(
AMIS
Alternate Multiplex Interrupt Specification
)
[v3.6]
{#idx73767}
{#idx73809}
{#idx73815}
{#idx73846}
INT 2D -
AMIS
Alternate Multiplex Interrupt Specification
v3.0+ - DETERMINE CHAINED INTERRUPTS
{#idx74053}
{#idx74072}
{#idx74088}
INT 2D -
AMIS
Alternate Multiplex Interrupt Specification
v3.0+ - GET PRIVATE ENTRY POINT
{#idx73959}
{#idx73980}
INT 2D -
AMIS
Alternate Multiplex Interrupt Specification
v3.0+ - INSTALLATION CHECK
{#idx73858}
{#idx73880}
{#idx73889}
{#idx73898}
{#idx73935}
INT 2D -
AMIS
Alternate Multiplex Interrupt Specification
v3.0+ - REQUEST POP-UP
{#idx74028}
INT 2D -
AMIS
Alternate Multiplex Interrupt Specification
v3.0+ - UNINSTALL
{#idx73985}
{#idx74023}
INT 2D -
AMIS
Alternate Multiplex Interrupt Specification
v3.5+ - GET HOTKEYS
{#idx74098}
{#idx74117}
{#idx74133}
{#idx74137}
{#idx74146}
{#idx74154}
INT 2D -
AMIS
Alternate Multiplex Interrupt Specification
v3.6 - GET DEVICE-DRIVER INFORMATION
{#idx74161}
{#idx74172}
{#idx74192}
INT 2D - Burnout Plus v3.00 - GET STATE/CONTROL INFORMATION
{#idx74251}
{#idx74260}
{#idx74301}
INT 2D - CDTSR - DISABLE POPUP
{#idx74465}
INT 2D - CDTSR - ENABLE POPUP
{#idx74498}
INT 2D - CDTSR - GET INTERNAL VARIABLE TABLE
{#idx74338}
INT 2D - CDTSR - REPROGRAM CDTSR
{#idx74435}
INT 2D - DAISY.SYS - BROADCAST: CHAIN RESCANNED
{callout or callback}
{#idx74648}
INT 2D - dLite 1.0+ - CHECK FOR dPressed FILE AND GET COMPRESSED SIZE
{#idx74452}
INT 2D - dLite 1.0+ - CHECK FOR dPressed FILE AND GET ORIGINAL SIZE
{#idx74411}
INT 2D - dLite 1.0+ - GET PARAMETER BLOCK ADDRESS
{#idx74229}
INT 2D - FREEVER - DISABLE
TSR
(Terminate and Stay Resident) A program which remains in memory after terminating in order to provide services to other programs or the user. The name comes from the name of the DOS function call used to remain in memory after termination.
{#idx74543}
INT 2D - FREEVER - ENABLE
TSR
(Terminate and Stay Resident) A program which remains in memory after terminating in order to provide services to other programs or the user. The name comes from the name of the DOS function call used to remain in memory after termination.
{#idx74528}
INT 2D - FREEVER - GET ORIGINAL DOS VERSION INFO
{#idx74480}
{#idx74486}
INT 2D - FREEVER - GET TaskMAX STATUS
AT
IBM PC AT
INSTALLATION
{#idx74579}
{#idx74583}
INT 2D - FREEVER - GET
TSR
(Terminate and Stay Resident) A program which remains in memory after terminating in order to provide services to other programs or the user. The name comes from the name of the DOS function call used to remain in memory after termination.
STATUS
{#idx74558}
INT 2D - FREEVER - SET VERSION NUMBERS
{#idx74513}
INT 2D - KEYBIT Lite v5+ - GET POINTER TO STATUS BYTE
{#idx74365}
{#idx74375}
{#idx74391}
{#idx74403}
INT 2D - RAMLIGHT v1.0 - GET MONITORING INFORMATION
{
undocumented
Information about a product which is not publicly available from the manufacturer, and must be determined by reverse-engineering (disassembly, trial-and-error, etc.). Undocumented information tends to change -- often dramatically -- between successive revisions of a product, since the manufacturer has no obligation to maintain compatibility in behavior which is not explicitly stated.
}
{#idx74317}
INT 2D - RATSR 2.0+ - GET STATUS
{#idx74207}
{#idx74222}
INT 2F - BMB Compuscience Canada Utilities Interface - INSTALLATION CHECK
{#idx75048}
INT 2F - FREEVER v1.0+ - INSTALLATION CHECK
{#idx94794}
{#idx94801}
{#idx94803}
{#idx94808}
INT 2F - TesSeRact RAM-RESIDENT PROGRAM INTERFACE
{#idx85682}
INT 2F - THELP v3.0 - INSTALLATION CHECK
{
undocumented
Information about a product which is not publicly available from the manufacturer, and must be determined by reverse-engineering (disassembly, trial-and-error, etc.). Undocumented information tends to change -- often dramatically -- between successive revisions of a product, since the manufacturer has no obligation to maintain compatibility in behavior which is not explicitly stated.
}
{#idx92391}
INT 32 - NOISE.SYS 0.53 -
API
(Application Program[ming] Interface) The defined set of calls which a program may make to interact with or request services of the operating system or environment under which it is running. Because the inputs and outputs of the calls are well-defined, a program using the API can continue using the identical calls even if the internal organization of the program providing the API changes.
{#idx98476}
INT 32 - NOISE.SYS v0.55+ - GET DEVICE DRIVER HEADER
{#idx98522}
INT 66 - MicroHelp Stay-Res Plus - ???
{#idx115677}
INT 66 - MicroHelp Stay-Res Plus - FIND PROGRAM NAME
{#idx115706}
INT 66 - MicroHelp Stay-Res/Stay-Res Plus - UNINSTALL
{#idx115693}
INT 7D -
[obsoleted proposal]
- ALTERNATE MULTIPLEX INTERRUPT
{obsolete}
{#idx124102}
INT F1 - Common ISDN
API
(Application Program[ming] Interface) The defined set of calls which a program may make to interact with or request services of the operating system or environment under which it is running. Because the inputs and outputs of the calls are well-defined, a program using the API can continue using the identical calls even if the internal organization of the program providing the API changes.
(CAPI)
v1.1 -
"API-REGISTER"
- INITIALIZE CAPI
{#idx132153}
INT F1 - Common ISDN
API
(Application Program[ming] Interface) The defined set of calls which a program may make to interact with or request services of the operating system or environment under which it is running. Because the inputs and outputs of the calls are well-defined, a program using the API can continue using the identical calls even if the internal organization of the program providing the API changes.
(CAPI)
v2.0 -
"CAPI_REGISTER"
- INITIALIZE CAPI
{#idx132194}
MEM 0040h:000Eh - SEGMENT OF EXTENDED
BIOS
(Basic Input/Output System) A set of standardized calls giving low-level access to the hardware. The BIOS is the lowest software layer above the actual hardware and serves to insulate programs (and operating systems) which use it from the details of accessing the hardware directly.
DATA SEGMENT
(
PS/2
IBM PS/2, any model
, newer BIOSes)
{#idx161160}
Notes
{#idx168171}
PORT
IBM PC Portable (uses same BIOS as XT)
0330-0333 - Adaptec 154xB/154xC
SCSI
(Small Computer Systems Interface) A system-independent expansion bus typically used to connect hard disks, tape drives, and CD-ROMs to a computer. A host adapter connects the SCSI bus to the computer's own bus. See also ESDI, IDE.
adapter
(default address)
{#idx145912}
Ralf Brown Programs
{#idx177150}
{#idx177159}
{#idx177161}
{#idx177198}
Readme
{#idx177265}